QA

Quick Answer: How To Assemble Stove Pipe

What’s the trick to putting stove pipe together?

Does the crimped end of stove pipe go up or down?

The crimped end of the stove pipe goes down. Many people think the crimped end goes up to keep the smoke in the pipe but that is incorrect. First of all the smoke is not just going up on its own, it is being drawn up the chimney by the natural draft.

How do you connect two pieces of stove pipe?

How to Put a Stove Pipe Together Line Up Stove Pipe. Set a length of stove pipe flat on the floor with the two open ends of the center seam facing away from the floor. Align Seam Corners. Snap Pieces Together. Attach With a Screw. Align Stove Pipe Seams. Slide Pieces Together. Attach with Screws.

Do you screw stove pipe together?

Use three self-tapping pipe screws per joint. Space them at even intervals connecting the pipes securely together. Power screwdrivers are helpful with this action.

Does stove pipe need to be sealed?

The pipe connected to a wood or pellet stove should not need sealing unless it has a hole or leak in it. When conditions are right, the negative pressure and natural draw of the stovepipe causes the hot smoky air to rise through the pipe and out the chimney.

What is the 2 10 rule?

A chimney must project at least 3 feet above the roof on its shortest side and also be at least 2 feet above any roof structure that is within a 10 foot radius of the chimney. That’s it. Following this simple rule helps to ensure other structures on the roof do not interfere with the exhaustion of combustion gases.

How do you install a flue pipe?

Instructions on How to Install a Flue Pipe Buy the flue pipe you want to install. Run vertical pipe up through the ceiling and roof. Keep flue pipe as straight as possible for horizontal runs. Screw three sheet metal screws to connect the pipe sections, overlapping at least 2inches along the seams.

Does a wood stove pipe have to go straight up?

The pipe should be as straight and short as possible, with sections properly secured. If it must have angles, limit them to one or, at the most, two sweeping 90-degree elbows or the equivalent. The horizontal portion of the pipe should rise not less than one-quarter inch to the linear foot, to insure a good draft.

How do you separate stove pipe?

Put on some gloves and grab the pipe with both hands. Twist it back and forth. If it will not twist, bump it side to side with your palms until you hear a gritty sound, which means you have broken the creosote from the inside. Twist it back and forth again until it moves slightly.

Can you use single wall and double wall stove pipe together?

single wall pipe should fit into double wall without an adapter. Double wall insulated requires an adapter with a screw-on end to fit the insulated pipe.

Can you mix single wall and double wall stove pipe?

Don’t mix them, go all the way with the double-wall. They make probe thermometers for reading double-wall stove pipe temps.

Can I use double wall stove pipe outside?

To do this requires that the pipe remain cool on the outside by having an internal design that creates a fire-safe venting system. The goal is to minimize the outside diameter of the pipe and the allowable distance from combustibles. This can be 2 inches for double-wall pipe and 1 ½ inches for triple-wall pipe.

Will a hot fire remove creosote?

Avoid Smoldering Many homeowners allow their fire to smolder until it burns itself out. As the fire begins to burn out more creosote is produced at the lower temperatures. Rather than allowing the fire to smolder, it should be extinguished.

Can you use duct tape on stove pipe?

Sheetmetal flue pipes, on the other hand, carry combustion gases from the furnace or the boiler to the chimney. Fiberglass ducts require an aluminum foil tape, while sheetmetal ducts are sealed with metal-foil tape, professional-grade duct tape or mesh-reinforced mastic.

Can you use aluminum tape on stove pipe?

Guest. If you want to be able to take the pipe apart, use the foil tape on the interior joints..the outside joints do not need to be sealed at all. I use the foil furnace tape they sell at Home Depot or Lowes on the interior pipes, and have never had any problems.

How far should stove pipe be from roof?

In essence, any chimney, stove pipe or other heating exhaust vent should be 3 feet (1 meter) above the roofline or 2 feet (61 centimeters) above any part of the building in a 10-foot (3-meter) radius.

How long should a stove pipe be?

Maximum overall length of straight pipe: 3 m (10 ft.) The assembly should be as short and direct as possible between the stove and chimney. The use of two 45 degree elbows is often preferable to a single 90 degree elbow because less turbulence is created in the exhaust flow and they result in less horizontal run.

How far does chimney have to be from roof?

The most common of these being the 2 foot, 10 foot, 3-foot rule. Roughly this means that a chimney should be 3 feet higher than the point it passes through a roof, while also being at least 2 feet taller than any part of a building that’s within 10 feet of the chimney.

How do you secure a flue pipe?

One end of the chimney pipe will be crimped and this is where you’ll slide the stove pipe over, pressing them together firmly. Next, you’ll just need to drill through the sheet metal with the right drill bit, placing a self-tapping screw against the stove pipe’s overlap to secure it.