QA

How To Install Range Hood Ducting

What type of duct is best for venting a range hood?

Rigid duct is the best type of duct to vent your range hood. It requires a one-time installation and little to no maintenance as long as you clean your range hood filters. Most rigid ductwork is made from durable stainless steel, as opposed to rigid ductwork which is aluminum or flimsy plastic.

How do you vent a range hood on an outside wall?

Attach a wall or roof cap to the exterior wall or roof. Determine where you want to vent your range hood. Install your ductwork in the shortest unobstructed path to the outside of your home. Cut a hole 1-2 inches larger than your ductwork where you’ll run the duct from your hood. Attach the range hood to your ductwork.

Can I use PVC pipe to vent a range hood?

The code does not allow this material. Range hoods shall discharge to the outdoors through a duct. The PVC duct extends not more than 1 inch (25 mm) above the indoor concrete floor surface. The PVC duct extends not more than 1 inch (25 mm) above grade outside of the building.

Can you use PVC duct for cooker hood?

PVC ducting is the cheapest one available, but is highly versatile and can be used in the majority of general ventilation connection applications, including cooker hoods.

How do you seal cooker hood ducting?

Here’s how. Extend your duct down to attach it to the transition piece. Use aluminum duct tape to seal the vent. Secure the duct tape firmly to the transition piece. Test the range hood before installing the chimney. If air leaks, apply a second piece of duct tape.

How do you measure a duct for a range hood?

Here is a Breakdown of the Duct Size You Need Based On Your Range Hood’s CFM. If you have a range hood with a CFM of 0-400, you will need a minimum duct size of 4”. If your hood is between 401 and 600 CFM, you need a minimum duct size of 6”. If your hood is between 601 and 900 CFM, you need a minimum duct size of 7”.

Do range hoods need to vent outside?

Range hoods do not have to be vented to the outside. But, ducted range hoods are almost always preferred over ductless hoods. They remove all the smoke and cooking exhaust from your kitchen, while ductless hoods recirculate your cooking exhaust back into your kitchen.

Can I vent my range hood into the soffit?

You must not vent into the soffits, or even under the soffits unless you are more than a foot and a half below the soffit to allow the wind to dissipate the moisture before it rises back up into the attic.

Should I vent my range hood through the roof?

If a roof is not vented, then grease, dirt, smoke, and chemicals will build up inside your attic. It can be dangerous to your health to keep these contaminants inside your home. Venting your range hood into the attic essentially defeats the purpose of having a ducted range hood.

Can you vent range hood through roof?

Yes, you can vent a range hood through the roof using a 6” single wall pipe. You can buy the proper flashing to install it on a flat roof and a roof cap that has screen around it to prevent insects from entering.

What is code for a range hood?

Although the international CFM code for range hoods is 100CFM, some local authorities allow for range hoods with slightly lower or higher CFM than this, depending on the type of your cooking, and the square footage of your cooktop.

Can you use PVC for ventilation?

PVC is used for exhaust vents because it can handle the volume of forced exhaust, and the exhaust typically travels a direct route over short distances. An HVAC system for a home carries much larger quantities of air, and is piped from the basement throughout the home.

How long can a cooker hood duct be?

There are generally 3 sizes 100mm (4″), 125mm (5″) and 150mm (6″). You now know which size ducting to buy, the larger the ducting the better, so you can go up a size but it is important NOT to reduce the size of the ducting, as this may void your warranty!.

What is the max recommended length of flexible duct?

Flexible air connectors which are listed to UL 181 are allowed by the standard in lengths up to 14 feet. This product is specifically evaluated for the maximum length up to 14 feet, and the manufacturer’s installation instructions are reviewed to ensure proper installation up to this length.

How do you seal plastic ducting?

Aluminium duct tape is a very common method of sealing plastic duct runs; however, cloth tape also provides a very tight and very long-lasting air-tight seal. Ducting sealant or caulking is a better option to give an airtight but permanent seal.

Can you duct tape a range hood?

Don’t use duct tape, use mechanical fasteners, foil tape, mastic, or all three. Duct tape is for wallets. Exhaust hoods installed over broiler units should have at least 24 inches clearance above the cook top and the hood should extend the full width and depth of the cooktop.