How To Measure A Roof For Metal Roofing

Here’s our step-by-step guide for measuring the total roof area for installation: Step 1: Start by sketching out a top-down view of your home’s roof. Step 2: Measure the length of your roof. Step 3: Next, figure out the width of the metal that you’re installing. Step 4: Repeat Step 3 for the other side of the roof.

How do you measure for a metal roof?

Divide the length of your roof by the width of the metal. In our example we will use 24-inch standing seam roofing, so we will divide 360 inches by 24, which equals 15. This is the number of metal panels needed for one side of the roof.

How do I figure out how many sheets of roofing I need?

Divide the total roof area by the effective area of a single sheet and round up the result to the next whole number. The result is the number of sheets required.

How do I measure my roof?

To find your roof’s total square footage: Measure the length and width of each plane on the roof (including dormers) then multiply length times width. Add the square footage of each of the planes together.

How many inches do you overlap metal roofing?

Install Metal Panels Align the first metal roofing panel so that it overlaps the edging by 1/2 to 3/4 of an inch and is square to the roof line. Be sure the larger edge is laid so that the small edge of the next panel will overlap it.

How much overhang should a metal roof have?

A typical metal roof overhang may be 2 to 4 inches, or even less. Some slight overhang is recommended, in conjunction with a drip edge flashing, to prevent water from getting under the roofing and onto underlying wood.

What is the standard width of metal roofing?

The two most common widths are 26 and 36 inches. Other standard widths include 24 and 39 inches. When calculating coverage using the width and length of corrugated roofing, keep in mind that each piece will need to overlap by several inches.

How do you measure a corrugated roof?

On the roof plan, measure the distance from the line of the ridge to the outside of the fascia, which in the example we’ve provided is half the span or 4000mm. Multiply this measurement by the Sheet Length Roof Slope Factor to find the length of the sheet required to span from the ridge to the fascia.

What is the standard size of a roofing sheet?

Blue MS Metal Roofing Sheet, Dimensions: 8 X 4 Feet, Thickness of Sheet: 2 to 3 mm.

How do you figure linear feet for a roof?

You can determine the length and width by simply using the dimensions from the roof plan. Therefore, you can find the perimeter of a hip roof or a hip and gable roof by using the same formula used to find the perimeter of a flat roof. Perimeter = 2(25′ + 30″) = 110 linear feet.

How much should corrugated sheets overlap?

Corrugated sheeting should always overlap by a minimum of one corrugation, this can be known as side laps. When overlapping corrugated sheeting its advised you use cladco lapping tape. For maximum sheet lengths in corrugated, we can supply 5m in a 0.5mm thickness and up to 6m length in the 0.7mm thickness.

How do you measure a roof online?

Step Two: Begin Measuring Your Roof Frame your home back to the top shot. Click the ruler icon on the left side of your screen. Switch the unit of measurement to feet. Click on a starting and stopping point, and you’ll get an estimated measure of distance. Start logging in your measurements.

What is the screw pattern for metal roofing?

Lap screws are spaced 12” to 18” on center. The panel screws are spaced out so that every third corrugation has a screw including both sides of the panel sidelap. When the corrugated sheeting is 39” wide instead of 37” wide the screw placement will be slightly different as shown in the diagram below.

Is a drip edge necessary on a metal roof?

A drip edge is not needed for metal roofing. If the metal roof is hanging over an inch, the water will be directed away from the fascia anyway if at a slant. However, it is highly recommended to install a drip edge to save from water damage later on.

Do I need furring strips under metal roof?

When installing a metal roof over an existing roof, insulate the spaces between the wood strips with rigid insulation to prevent condensation before installing the roofing. You also need to add furring strips. Twenty-four inches is a common spacing of furring strips for a metal roof.

Do you put felt under a metal roof?

Some might choose to skip using underlayment to save money. However, the metal roof underlayment acts as an added layer of protection. You can save money by using underlayment because it will help you avoid problems that would need to be fixed. The short answer is yes, your metal roof does need underlayment .

What size are corrugated roofing sheets?

These galvanised roofing sheets are available in both 0.5mm and 0.7mm thicknesses.

How wide is a corrugated sheet?

The actual sheet width of corrugated sheets is 850mm.

How much should a corrugated roof overlap?

An overlap of 150mm is often recommended for roofs with 10° pitches, whilst 300mm is recommended for 5° pitches. Always allow for an overhang of at least 60-70mm so that water can run off without coming into contact with rafters or purlins, which can lead to damp and structural weakness.