Question: How To Test Fan Limit Switch

Watch the oil or gas burner: The furnace oil or gas burner should turn ON and subsequently the FAN LIMIT control should turn the burner back OFF when the temperature in the supply air plenum reaches the FAN LIMIT set point. Watch the dial on the fan limit switch moving to confirm its operation.

Can you bypass furnace limit switch?

When testing if a switch is good or bad, it can be bypassed for a short time. This is a common method to see if the switch needs a replacement. The limit switch turns the furnace off when it becomes too hot, which prevents the heat exchanger from becoming damaged.

What happens when a limit switch goes bad?

One common symptom of a malfunctioning limit switch is a blower fan that doesn’t shut off. A bad switch also can prevent a furnace from operating at all. If the switch has completely failed and is stuck in the open circuit (off) position, the furnace won’t run. The same effect can result from repeated overheating.

Should a limit switch be open or closed?

The limit switch is a normally closed switch in series with the sail switch and the thermostat. Being temperature actuated, it is designed to “snap open” when an over temperature condition occurs. Thus the switch is normally opening under full load conditions and that causes arcing of the contacts.

How do you reset the limit switch on a furnace?

How to Reset Furnace Limit Switch. Once the problem affecting your furnace has been identified and corrected, you should reset your furnace to continue enjoying the warmth on your home. In most gas furnace, this is done by simply shutting off the power supply and turning it back on after 20 or so seconds.

How do you reset the fan limit on a furnace?

How to Reset a Furnace Limit Switch Locate your furnace’s heating duct. Locate the white limit switch. Look at each arm to identify the settings. Identify the component (setting) located in between the two arms. Set the temperature on the middle component to approximately 105 to 115 degrees Fahrenheit.

How does a fan limit switch work?

To put it very simply, the furnace fan limit switch is a control that tells your furnace’s fan when to turn on and off. So, when the furnace isn’t on, it tells the blower not to operate (and send cold air into your home) and when the furnace is on, it tells the blower to turn on and start circulating the warm air.

What causes a limit switch to open?

Limit switch codes The limit switch shuts off the burner when the temperature exceeds a preset temperature. When the temperature reduces to normal, the burner will come back on. The most common reason for limits to open is a plugged filter or a dirty blower wheel.

Are furnace limit switches normally open?

The fan limit switch is normally open and closes when the temperature reaches its preset value, whereas the high limit switch is normally closed and opens when the temperature reaches its threshold value.

Should a limit switch have continuity?

I believe high limit switches are normally closed, and they should always fail open. Which means when they go bad, or the temperature gets too high they open the circuit. To test a limit switch, you’ll want to check continuity to determine what state the switch is in. If there is a serviceman switch, turn it off.

Can a limit switch be reset?

Senasys’ manual reset limit switches are a temperature sensing device with normally closed contacts. Once that limit is reached, a human must manually press the red reset button for the switch to return back to the normally closed state.

At what temperature does the fan limit normally closed?

This is best left to a furnace repair specialist when trying to troubleshoot problems. The standard settings for most furnace fan limit switches are 200°F to shut off the burner, 130°F to turn off the blower, and 100°F to turn the blower back on.

What is the usual setting for the limit on the fan limit switch of a warm air furnace?

What is the usual setting for the limit on the fan/limit switch of a warm air furnace? 180°F to 200°F.

How do you clean a limit switch?

How to clean or replace a furnace high limit switch Shut off power to the furnace and remove the access panel. Locate the high limit switch. Remove the high limit switch from the plenum by unscrewing it and taking out the wire connectors. Clean the limit switch sensor using fine-grit sandpaper or a scouring pad.

How much does it cost to replace a limit switch?

You’ll need to get a limit switch from the same company that makes your furnace. This component could cost anywhere from $4 to $25, depending on your original equipment manufacturer.

Why does my furnace high limit switch keep tripping?

A high limit switch will keep tripping due to a dirty flame sensor, short cycling, obstructed airflow, or a defective switch. These lead to overheating within the gas furnace that triggers tripping as a safety measure to prevent fires. Clean and replace dirty and worn-out parts to fix the problem.

Why won’t my furnace fan shut off?

If your furnace fan won’t turn off, you most likely have one of these 3 problems: Your furnace fan limit switch is set to “manual override” The fan limit switch is faulty and needs to be replaced. There’s a problem in your thermostat wiring.