QA

Quick Answer: How To Test Hot Water Heater Heating Element

How do I know if my hot water heater element is bad?

Touch a probe on the multitester to each screw on the element. If you get no reading, or a maximum reading, the element is bad. Elements do have some resistance, so a reading of 10-16 ohms is normal, with higher ohm readings for 3,500 watt elements and lower readings for 5,500 watt elements.

How do I know if my water heater element is working?

How do you test a heating element for open or busted?

Place test probes of the OHM meter on both screw terminals. If the OHM meter does not register a resistance, the element is open and should be replaced.

How do you test a thermostat on a electric water heater?

Test the lower portion of the thermostat, by touching one lead to the common terminal (next to the temperature setting) and the second lead to the left heating element terminal. If the water in the tank is below the thermostat’s set temperature, the multimeter should read close to zero ohms of resistance.

How many ohms should a water heater element read?

Touch the other probe to the other screw attached to the face of the heating element. If the heating element is functioning properly, the multimeter should read between 10 and 30 ohms. If there is a very low reading or zero reading, the heating element isn’t working and must be replaced.

Should a water heater element have continuity?

If the ohmmeter needle moves or you get some Ohm reading (any resistance other than infinity) then the heating element is OK . In sum, if there is “continuity” through the heating element it is working. If there is no continuity (no electrical current can flow) then the element has failed.

How do you find the resistance of a heating element?

Know the resistance of the element should be this can be calculated using known values: R = (V x V) / P [Where V is the voltage powering the element, P is the power the element uses and R is the resistance.].

Will a water heater work with one element?

Yes, a water heater can still run if the bottom element quits. In most water heaters, the top heating element controls the thermostat and will still work even if the bottom element fails. So provided the top heating element is working, it can still produce some hot water even if the bottom heating element fails.

How many volts should a hot water heater element have?

Most residential electric water heaters use 240 volts. Their are single element water heaters that operate on 120 volts and single element water heaters that operate on 240 volts.

Which element heats first on a water heater?

Initial start up: When the tank is full of cold water, the upper thermostat will take priority and heat up the top portion of the water to the setting of the thermostat. Once that temperature has been reached, the thermostat will then flip power down to the lower thermostat.

What happens when a heating element goes out in a water heater?

If you have an electric water heater, the heating elements inside the tank can break and lead to a loss of hot water. Sometimes, your water will slowly start to cool down and this could be because the element has burned out. If the second element fails, you’ll be left with only cold water.

How do I know if my thermostat or element is bad?

Answer: Check for voltage at the element. If it has voltage the new element isn’t working. If no voltage there is a problem with the thermostat, either it is set too low or not functioning properly.

How do I know if my thermostat is working properly?

When a thermostat is working properly, it should display an accurate temperature of what it feels like inside your home. But if the room feels much hotter or colder than the display temperature, that means your thermostat can’t accurately measure the room’s temperature.

How many ohms should a 4500 watt water heater element have?

A 3,500-watt element should register 16 ohms, a 4,500-watt element should register between 12 and 13 ohms, and a 5,500-watt element should register between 10 and 11 ohms.

How do you check a water heater element for continuity?

As a confirmatory test, leave one probe on one of the heating element screws, and use the other to touch the metal surface of the water heater. If there is a reading on the multimeter (or if it beeps), the heating element is grounded and will need a replacement.

How do you find the current in a heating element?

I=V/R. If you want to draw more current, you need lower resistance. Power dissipated is voltage times current, so putting it together, you get .

How many ohms is a 3kw element?

The resistance of a 3kw immersion heater should be approximately 20 ohms.

Do heating elements have high resistance?

Heating elements don’t have a high resistance: for example a 1kW 220v heating element will have a resistance around 50 Ohms and a 2kW one will be about 25Ohms. If you’re in a country using 110V then a 2kW element will have a resistance of only 6.05 Ohms.

Does the top or bottom element heat first?

The top element is always the first one on. In fact the bottom element does not receive power until the top thermostat is satisfied.

Should both thermostats on an electric water heater be set the same?

The majority of electric water heaters have two thermostats: an upper and a lower, located under two control panels. To ensure your electric water heater works as efficiently as possible, you should set both of the thermostats at the same temperature.

Are top and bottom water heater elements the same?

Each element has its own thermostat, and only one element runs at a time. The top element turns on first to start the warming process. Once the water in the top half of the tank reaches the set temperature, the top element turns off, and the bottom element turns on to heat the rest of the water.