How To Wire A Disconnect Switch

What is line and load on a disconnect?

Understanding the Terms “Line” and “Load” in Electrical Systems. In the electrical trades, the terms “line” and “load” are shorthand words that refer to the wires that deliver power from the source to a device (line), vs. those that carry power onward to other devices further along the circuit (load).

When should a disconnect switch be installed?

An Electrical disconnect switch is necessary for most 240-Volt appliances according to electrical safety codes. The only devices which are exempted from this requirement are those that are in sight and within 50 feet of the breaker box.

How does an electrical disconnect work?

Disconnect switches work in conjunction with circuit breakers that interrupt the flow of electricity along a circuit when the current exceeds the circuit’s capacity. Disconnect switches can work with AC or DC systems and are also available for single-phase and three-phase power.

What is the difference between a main disconnect and a service disconnect?

Also called the service disconnect, this is the first disconnect device after the utility meter. This disconnect may be a special breaker switch housed in an exterior box enclosure, or it may simply be the main circuit breaker on the home’s main service panel.

Can a disconnect be used as a junction box?

Enclosures for switches or overcurrent devices shall not be used as junction boxes, auxiliary gutters, or raceways for conductors feeding through or tapping off to other switches or overcurrent devices, unless adequate space for this purpose is provided.

What is code for AC disconnect?

The 2008 National Electric Code requires: 440.14 Location. Disconnecting means shall be located within sight from and readily accessible from the air-conditioning or refrigerating equipment. The disconnecting means shall be permitted to be installed on or within the air-conditioning or refrigerating equipment.

What size breaker do I need for a 30 amp disconnect?

Sizing an air conditioner circuit breaker Breaker or Fuse (amps) Min. copper wire size (AWG) 30 10 40 8 55 6 70 4.

Can I use a 60 amp disconnect on a 30 amp breaker?

As long as the circuit is on the proper size breaker, there’s nothing wrong with using a 60 AmpDisconnect on a 30 Amp unit.

How do I know if a wire is load or line?

Load Wire – Generally connected to the top half of your switch. If the wire is coming from the top of the switch box, it is likely your load wire. Line Wire – Generally connected to the bottom half of your switch. In some cases, line wires are marked with “line”, “pwr”, or a lightning bolt symbol.

Can a circuit breaker be used as a disconnect switch?

Yes it can. Electric water heaters and dishwasher use the breaker as a service disconnect often. A permanently installed breaker lock enabling the technician to install a lock on a open breaker is required.

What is a fusible safety switch?

Fusible safety switches combine fuses with the switch in a single enclosure, providing an easy means to manually open and close the circuit while the fuses protect against overcurrent and short circuit.

What is the 6 breaker rule?

The “six breaker throw rule” was a requirement in the National Electrical Code that a service must have have a main disconnect that shuts off all power and it cannot take more than six switch throws to do it, and the main disconnect(s) also must be clearly marked, as in the photo above.

How much does it cost to install a disconnect switch?

The average cost to install an AC disconnect ranges from $200 and $500, though the cost can go up to $3,000 if you don’t have ample space or amperage on your circuit breaker. An AC disconnect is best installed at the time you install your AC unit but can be added afterward.

Does a service disconnect need to be fused?

For these systems, a current-limiting is required at some point in the circuit. So if the upstream device is a circuit breaker, the local disconnect will need to be fused in order to have an installation that meets UL requirements (and hence, NEC requirements).

When should you use a fused disconnect switch?

Fused disconnect switches are often used in circuits that have extremely high currents, with the fuse guaranteeing that the circuit will be disconnected if there is a problem.

What are the different types of disconnect switches?

There are two basic types of disconnect switches: battery disconnect switches and electrical disconnect switches. A battery disconnect switch is a knife switch that prevents unwanted drain from a vehicle battery when the vehicle isn’t in use or is in storage.

Why do I need a fused disconnect?

The goal of a fused disconnect is to open a circuit and disengage power quickly and definitively in the case of an overload or short. When potentially harmful electrical problems arise the fused disconnect detects them, the fuse blows, and the equipment is shut off automatically.

How high can you mount a disconnect?

The NEC does not mandate a minimum mounting height for panelboards, disconnects, or meter enclosures. But switches, and circuit breakers used as switches, shall be installed so the center of the grip of the operating handle of the switch or circuit breaker, when in its highest position, is not more than 6 ft 7 in.

Which wire do you connect first hot or neutral?

In any electrical connection sequence you always connect the Ground first, the neutral then the hot. BUT and here is the main part of this – before making any connections you must make sure that the circuit you are working with is not energized.