QA

Question: What Does A Sump Pump Check Valve Do

Sump pump check valves are an important part of any sump pump system. Installed in the discharge pipe leaving your sump pump, the sump check valve prevents your pump from having to re-pump water it has already discharged.

What happens when a check valve goes bad in a sump pump?

A check valve in the sump pump’s discharge line avoids the pumped water from running back into the pit again. Without it, a sump pump would be forced to move the same water twice which can cause the pump to burn out prematurely.

Where should a sump pump check valve be located?

The most suitable location for a sump pump check valve is close to the floor level to minimize the volume of water that drains back at the end of each pumping cycle and it is a convenient location for easy servicing or replacement of the valve.

Is a check valve necessary on a sump pump?

Sump pump check valves are an important part of any sump pump system. Installed in the discharge pipe leaving your sump pump, the sump check valve prevents your pump from having to re-pump water it has already discharged.

How do I know if my sump pump check valve is bad?

How to Tell if the Check Valve is Bad Check for leaky or moisture on seals, connections and valve. Fill the put 1/4 to 1/2 with water and see if it drains. Watch for water backwash into your basin during testing and rainstorms.

Is a check valve necessary?

Do I need a check valve? A check valve is a valve that is used to prevent backflow in a piping system. Even if a pump does have a built-in check valve, we recommend that a check valve be installed in the discharge line within 25 feet of the pump and below the draw down level of the water supply.

What does a check valve do?

A check valve is a device that only allows the flow of fluids in one direction. They have two ports, one as an inlet for the media and one as the output for the media. Since they only allow media flow in one direction, they are commonly referred to as ‘one way valves’ or ‘non return valves.

Why is my sump pump check valve so loud?

Waste lines from a sewage ejector or sump pump use a check valve to stop wastewater from flowing back into the basin. When these valves shut, they can make a thud loud enough to be heard throughout the house. To quiet them, replace the old check valve with a “silent” or “soft close” check valve.

How close should check valve be to sump pump?

Best height ( unless owner’s manual states otherwise) is two to three feet off of the top of the sump pit. This way your sump pump motor doesn’t have to work as hard as when your check valve is in lower position.

How often should a check valve be replaced?

While typical component lifespans are application specific, manufacturers suggest metal and plastic check valves should be replace every 5-7 years whereas check valves manufactured from rubber may remain fully serviceable for up to 35-50 years.

Why does my sump pump make a loud banging noise?

The loud banging noise you hear when the sump pump turns on or off is caused by the check valve. This in turn shuts the check valve, preventing it from flowing back into the pump. The loud banging noise is caused by the sudden change in pressure inside the pump and its hoses.

What happens when a check valve goes bad?

A check valve is designed and installed into a line or pipe in such a way to allow the fluid to flow only one direction. When a check valve fails it allows the fluid o flow in either direction. This action may cause a pump to fail or the fluid to flow back through the pump when it is stopped stopped.

What happens if a check valve is bad?

Symptoms of a Failing Check Valve For example, failing check valves will start to vibrate and even lose some internal parts when problems begin to arise. Other symptoms of check valve failure include reverse flow and excessive component wear and damage. Check valves will also emit noises as they start to break down.

Can a check valve cause low water pressure?

No. A check valve prevents backflow. A pressure reducing valve can regulate water pressure. A PRV can be either a fixed outlet pressure or a dial up type can be adjusted to suit application.

Should a check valve be before or after pump?

On booster pump applications, a check valve can be placed on the suction or discharge of a centrifugal pump. If an additional check valve is required, it should be placed after the pressure tank to allow the pump and discharge pipe to remain pressurized.

Should a bilge pump have a check valve?

Parts Needed. And no, you should not use a check valve in the bilge pump line to prevent the back flow of water. The use of a check valve is not recommended due to the potential for sticking and causing the pumping system to fail. Therefore, it’s a good idea to remove as much of that water as possible.

Is a check valve the same as a backflow preventer?

Check valves are used in a wide variety of equipment, cars, planes, pneumatic and fluid systems, while backflow preventers are typically used in plumbing systems for structures. A check valve has a variety of roles but is mostly used to regulate and control the flow of fluids, especially into pumps.

What is cracking pressure on a check valve?

An important concept in check valves is the cracking pressure, which is the minimum upstream pressure at which the valve will operate. Typically, the check valve is designed for controlling of fluid flow in one direction; therefore, it can be specified for a specific cracking pressure.