QA

What Size Circuit Breaker For Water Heater

Electric water heaters require a 240-volt dedicated circuit, which serves only the water heater and no other appliances or devices. The circuit wiring typically includes a 30-amp double-pole breaker and 10-2 non-metallic (NM) or MC cable.

What size breaker do I need for a 50 gallon hot water heater?

The standard for water heater circuits is #10, two conductors with ground (10/2) and a 30 amp circuit breaker for a water heater. If you are running cable anyway, just run #10 and replace the breaker so it’s done right, once and for all.

Can I use a 40 amp breaker for a 30 amp water heater?

If you are sure there is (at least) #8 wire all the way from the breaker to the water heater, you can just replace the 30A breaker with a 40A breaker, but if and only if you have verified the size of the wire throughout the entire circuit.

What size breaker do I need for a hot water heater?

Electric water heaters require a dedicated 240-volt dedicated 30-amp circuit and a 10-2 non-metallic (NM) or MC cable. This means the breaker only powers the water heater and no other appliances. A 30-amp circuit breaker can power all 4500watt water heaters regardless of gallon size.

What size breaker do I need for AO Smith 40-gallon water heater?

Now we can start with the calculations: A 40-gallon water heater should have an average 4500 Watt capacity and 240 V emf. Thus, a 25 or 30A breaker is sufficient for a 40-gallon breaker.

What size breaker do I need for a 4500 W water heater?

The right circuit breaker for this appliance with 4500 watts at 240 volts is either 25 amps or 30 amps. If the water heater isn’t rated as “continuous load”, then it would have been fine to use 100% of the circuit breaker’s rating.

Can I use 10 3 wire for a hot water heater?

Can I Use 10 3 Wire For A Hot Water Heater? You can use 10/3 wire. Use the red and black wires as hot conductors. The ground wire will run to the green screw.

What amp breaker do I need for a 40-gallon water heater?

For a 40-gallon heater, the average capacity is 4500 Watts with 240 Volts. Again, I = P/V; 4500W/240V = 18.75 amps. Then considering the continuous load (125% x 18.75A), we’ll get a total of 23.4 amps. With our answer, a 40-gallon water heater needs at least a 25-amp breaker, the closest to the amperage value.

Can I use a 50 amp breaker for a 30 amp water heater?

30 amps is where a 30 amp breaker should cut off, and to avoid that, you should only use 80% of the breaker’s capacity. So for a 30 amp breaker, you shouldn’t be using more than 24 amps. Using a 50 amp breaker and a dedicated outlet ensures that you don’t exceed the capacity of the circuit with that appliance.

Can I use a 40 amp breaker for a 50 gallon water heater?

Yes, if AND ONLY IF the wires from the breakers to the water heaters are sufficient to carry 40 amps (e.g. 8-gauge 90C THHN copper). The largest residential heating elements for a tanked water heater are 7000 watts.

How many amps is a double pole 30 amp breaker?

A 30 amp double pole or two pole breaker gives you a total of 30 amps on each legbefore it is supposed to trip. In the cases where a double pole breaker feeds a single load, such as for stove, clothes dryer, water heater etc. the majority of the load will be provided across the two halves of the split phase service.

What size wire would you run for a 30 amp breaker connected to a electric water heater?

Electrical wires Since the generic breaker size for water heaters is 30-amps, the best wire size is a #10 American Wiring Gauge (AWG).

How many amps does a 50 gallon electric water heater use?

A typical 50 gallon electric water heater runs at 4500 watts. In an electric circuit of 240 volts, 4500 watts is equivalent to 18.75 amps.

What size breaker do I need for a 240-volt water heater?

Electric water heaters require a 240-volt dedicated circuit, which serves only the water heater and no other appliances or devices. The circuit wiring typically includes a 30-amp double-pole breaker and 10-2 non-metallic (NM) or MC cable.

What size wire do I need for a 40-gallon electric water heater?

An average 40-gallon electric water heater requires 12 gauges of wire. You cannot use a 6 gauge or 10 gauge wire in that case. The current will overflow and the wire will start melting.

How many amps should a hot water heater pull?

What is the Standard Amperage for an Electric Water Heater? Most electric water heaters use 18.8 amps with 240 volts and a 4,500 watt heating element. A gas water heater uses less amps—about 12 Amps with 115 volts. The average residential container heater has a 40-gallon tank and usually requires a 30-amp breaker.

Can I replace a 3500 watt element with a 4500 watt element?

It is ok to install lower watt: replace 4500 with 3500 as long as voltage is same. Lower watt means less heat, so element can last longer.

What is 20amp wire?

Why Wire Gauge Is Important Wire Use Rated Ampacity Wire Gauge Low-voltage lighting and lamp cords 10 amps 18-gauge Extension cords (light-duty) 13 amps 16-gauge Light fixtures, lamps, lighting circuits 15 amps 14-gauge Kitchen, bathroom, and outdoor receptacles (outlets); 120-volt air conditioners 20 amps 12-gauge.

Can I replace a 4500 watt water heater with a 5500 watt?

You can definitely replace 4500 watt with 5500 watt and get 4-7 gallons more hot water from a tank.