QA

Question: What Size Duct For 1200 Cfm

At 600 CFM, the minimum duct size is 6”. At 900 CFM, the minimum duct size is 8”. Finally, at 1200 CFM and above, consider a 10” diameter duct or larger.

What size duct is needed for 1000 cfm?

Rectangular equivalent diameter for air flows between 100 – 50000 cfm. Air flow – q – (Cubic Feet per Minute, cfm) (m 3 /s) Rectangular Duct Sizes (inches) (mm) x (mm) Friction Loss (inH 2 O / 100 ft duct) (Pa/100m) 1000 (0.45) 10 x 14 12 x 12 0.15 1300 (0.59) 12 x 14 0.15 1400 (0.63) 12 x 15 0.15 1700 (0.77) 10 x 22 14 x 15 0.14.

How many CFM can a 12 inch duct handle?

The rule of thumb for a 12 inch duct is 715 cfm. You would need a 20 inch duct to handle 2000 cfm.

How do you calculate duct size from CFM?

Duct CFM Calculation Formula Room CFM = (Room load/Whole house load) ✕ Equipment CFM. 24,000 BTUs ÷ 12,000 BTUs in 1 ton = 2 tons ✕ 400 CFM per ton = 800 CFM. Room A = (2,000 BTUs ÷ 24,000 BTUs) ✕ 800 CFM. Room A = 66.67 CFM.

How many CFM is a 4 inch round duct?

Reviewing the chart, a 4” pipe will convey 395 CFM at 4500 FPM. This means that a 4” pick-up on a machine will use 395 CFM from the filtering system; or, if you know that a machine will require approximately 400 CFM to remove the waste, you should use a 4” pipe for that purpose.

How many CFM does a 6 inch duct have?

CFM Sizing Chart For Flex Round Ducts (50-1,700 CFM) Duct Size (Inches) Flex Duct Airflow (CFM) 5 inches 50 CFM 6 inches 75 CFM 7 inches 110 CFM 8 inches 160 CFM.

What size ductwork do I need for a 3 ton unit?

Multiply the tonnage, 3.5, by the total BTU per ton and this will give you the total BTU rating. Multiply 6 x 42 to determine the duct size of 252 square inches The clear are of the duct must be at least 252 square inches This measurement also includes the opening in the floor at the bottom of the return.

What happens if ductwork is oversized?

The Ducts Are Too Large Not much. This is what happens when your air ducts are too big for your system. Your system pushes air into the ducts, but the ducts are too large for it to build up any sustained amount of air pressure, and thus a “forced air” system doesn’t have any force.

What happens if ductwork is undersized?

Ducts that are undersized will increase the static pressure, which will result in excessive noise as air moves through the system. It is often loud enough to be distracting, so it will not be difficult to overlook and should be addressed, as undersized ducts overwork the heating unit.

What size should my return air duct be?

A typical supply vent is 4 by 10 to 12 inches and a typical return vent is 16 by 20 inches or larger. Houses often have two or more return collecting points, each with a filter, which join before re-entering the heating unit. Two-story houses will have one return downstairs and another upstairs.

What size duct do I need for a 12×12 room?

A 12×12 foot room will need a 4×8 inch supply duct to get an adequate CFM rate, which is about 144 CFM.

How do I know what size flex duct I need?

Measure the length and width of the room where the flex duct will be supplying the air. Multiply the length and width together to get the square footage of the room. For example, a 10-by-10 room will be 100 square feet.

What are standard duct sizes?

Rectangular HVAC Duct Sizing Rectangular or square ducting comes in standard sizes ranging from 3 inches by 7 inches to 35 inches by 40 inches. Sizing is based on airflow needs per cubic foot per minute, as well as velocity.

What size ductwork do I need for a 5 ton unit?

Using this approach, two 20-in. x 25-in. return grilles will be the right choice for a five-ton HVAC system in order to actually deliver 2,000 cfm back to the blower without causing the return to hemorrhage.

How many CFM is 100 square feet?

Example: For residential bathrooms up to 100 sq. ft. in area, HVI recommends an exhaust rate of 1 cfm per square foot. A bathroom is 6′ to 10′ or 60 square feet.

How much airflow does a room need?

That’s why we need to divide the total volume by 60; hence 4,800/60 = 80 CFM. Answer: You need an 80 CFM airflow (for 300 sq ft standard room and 2 ACH).CFM Chart For Common Room Sizes. Room Size: CFM (At 2 ACH) How many CFM for a 300 sq ft room? 80 CFM How many CFM for a 400 sq ft room? 107 CFM.

How far can you run 6 round duct?

When you go from 6″ round to 6″ oval, you get 110′ of equivalent length. Wow! That means that a fitting that is somewhere around 1′ in actual length reduces the air flow as much as 110′ of straight 6″ duct.

What is the good rule of thumb in sizing Ductworks?

Determining the Right Duct Size When you hire a professional to install your ductwork, they’ll often size your HVAC ducts using a rule of thumb that states an air conditioner with one-ton capacity should be installed for every 500 square feet of air-conditioned floor area.

Does register size matter?

Unless you are severely undersizing your register, the noise is really the only issue. So a bigger register will not help cool or heat your room better. Putting the register in a better location and making sure the air is shooting out in an efficient manner and at an efficient angle is key.