Question: How To Calculate Hvac Duct Size

To calculate the required equipment size, divide the HVAC load for the entire building by 12,000. One ton equals 12,000 BTUs, so if a house or office needs 24,000 BTUs, it will take a 2-ton HVAC unit. If you get an uneven number, such as 2.33 for a 28,000 BTU load capacity, round up to a 2.5-ton unit.

How do you measure HVAC duct size?

Measure the end of a square or rectangular duct each way to determine the size. If the duct fitting inside the wall transitions to a circular duct, measure inside the circular duct from top to bottom. Repeat this at the remaining grills and ducts throughout the house.

What size duct do I need for a 12×12 room?

A 12×12 foot room will need a 4×8 inch supply duct to get an adequate CFM rate, which is about 144 CFM.

How do you calculate CFM for a rectangular duct?

Calculating CFM CFM = FPM x Duct Cross Sectional Area. FPM = 4005 x √.45. FPM = 2,686. CFM = 2,686 x Duct Cross Sectional Area. A (Duct Cross Sectional Area) = X (height in feet) x Y (width in feet) A = 1.07 sq. feet. CFM = FPM x Duct Cross Sectional Area. CFM = 2,686 x 1.07 sq. feet.

How many CFM is a 12×12 duct?

12-Inch Rectangular Ducts Size Chart (150-3,050 CFM) 12″ Duct 12″ CFM 8×12 400 CFM 10×12 550 CFM 12×12 680 CFM 14×12 800 CFM.

What are standard duct sizes?

Rectangular HVAC Duct Sizing Rectangular or square ducting comes in standard sizes ranging from 3 inches by 7 inches to 35 inches by 40 inches. Sizing is based on airflow needs per cubic foot per minute, as well as velocity.

How do you tell what size duct you have?

If you have round ducts, you simply measure the diameter (D) of the duct (the cross-section). This will tell you what size duct to purchase to replace it. If you have rectangular or square ducts, measure the width (W) and height (H) of the duct and use these figures when buying new parts.

What size ductwork do I need for a 3 ton unit?

Multiply the tonnage, 3.5, by the total BTU per ton and this will give you the total BTU rating. Multiply 6 x 42 to determine the duct size of 252 square inches The clear are of the duct must be at least 252 square inches This measurement also includes the opening in the floor at the bottom of the return.

How many CFM do I need for 600 square feet?

160 CFM Room Size: CFM (At 2 ACH) How many CFM for a 600 sq ft room? 160 CFM How many CFM for a 700 sq ft room? 187 CFM.

How many CFM is 100 square feet?

Fan Sizing for Bathrooms Under 100 SQ. FT. The standard rule for bathrooms 100 square feet or smaller is one CFM per square foot of the bathroom. To find the square footage multiply the length of the bathroom by the width. Example: 10′ x 10′ bathroom = 100 square feet.

How many CFM can a 12 inch duct handle?

The rule of thumb for a 12 inch duct is 715 cfm. You would need a 20 inch duct to handle 2000 cfm.

What size duct is needed for 1000 CFM?

Rectangular equivalent diameter for air flows between 100 – 50000 cfm. Air flow – q – (Cubic Feet per Minute, cfm) (m 3 /s) Rectangular Duct Sizes (inches) (mm) x (mm) Friction Loss (inH 2 O / 100 ft duct) (Pa/100m) 1000 (0.45) 10 x 14 12 x 12 0.15 1300 (0.59) 12 x 14 0.15 1400 (0.63) 12 x 15 0.15 1700 (0.77) 10 x 22 14 x 15 0.14.

How do you calculate CFM for ductwork?

To calculate CFM, you need to know the size of your heating or cooling unit in tons. Multiply this number by 400, which is the average output of an HVAC unit. Then divide by the total square footage of your home. This will give you the multiplier for all your rooms’ CFM.

How many CFM is a 4 inch duct?

Reviewing the chart, a 4” pipe will convey 395 CFM at 4500 FPM. This means that a 4” pick-up on a machine will use 395 CFM from the filtering system; or, if you know that a machine will require approximately 400 CFM to remove the waste, you should use a 4” pipe for that purpose.

What size ductwork do I need for a 5 ton unit?

Using this approach, two 20-in. x 25-in. return grilles will be the right choice for a five-ton HVAC system in order to actually deliver 2,000 cfm back to the blower without causing the return to hemorrhage.

What is the good rule of thumb in sizing Ductworks?

Determining the Right Duct Size When you hire a professional to install your ductwork, they’ll often size your HVAC ducts using a rule of thumb that states an air conditioner with one-ton capacity should be installed for every 500 square feet of air-conditioned floor area.

How do you calculate duct insulation?

Measure the diameter of the duct then divide it by 2 to get the radius. Square the radius then multiply the radius by Pi, or 3.14. This will give you square inches of the duct. Divide that total by 144 to get square feet of the actual duct.

What happens if ductwork is undersized?

Ducts that are undersized will increase the static pressure, which will result in excessive noise as air moves through the system. It is often loud enough to be distracting, so it will not be difficult to overlook and should be addressed, as undersized ducts overwork the heating unit.

What size duct do I need for a 2.5 ton AC unit?

For instance a 2.5 ton system (Approximately 400 CFM per ton) would require (2) 14” flexible return ducts or (1) very short flexible 18” duct to move the 1000 CFM required by the 2.5 ton system.

Can ductwork be too big?

The Ducts Are Too Large Not much. This is what happens when your air ducts are too big for your system. Your system pushes air into the ducts, but the ducts are too large for it to build up any sustained amount of air pressure, and thus a “forced air” system doesn’t have any force.