QA

Quick Answer: What Is The R Value Of Blown In Insulation

Blown-in. If you are insulating an attic or wall cavities, blowing the insulating material in using pneumatic equipment ensures maximum coverage. You can also apply it over existing insulation. Blown-in fiberglass has an R-value of 2.2 to 2.7 per inch.

How many inches of blown insulation is R30?

Fiberglass Chart R-Value Thickness Bags / 1000 Sq Ft R49 16.25” 22.6 R44 14.75” 20.1 R38 12.75” 16.8 R30 10.25” 13.0.

What is the R-value of 10 inches of blown insulation?

R-value of Materials and Depths Material R-value/in 10″ Fiberglass (batt) 3.1 – 3.4 31.0 – 34.0 Fiberglass blown (attic) 2.2 – 4.3 22.0 – 43.0 Fiberglass blown (wall) 3.7 – 4.3 37.0 – 43.0.

What is the R-value of 14 inches of blown insulation?

Warm Climates (R-30 to R-49): Fiberglass (blown): 14” – 18” Fiberglass (batts): 11” – 14” Cellulose (blown): 11” – 13”.

What is the R-value of 4 inches of fiberglass insulation?

The R-value for fiberglass batts ranges from 3.1–3.4 per inch of thickness. For loose-fill fiberglass insulation in an attic, the R-value is 2.2–4.3 per inch and for the wall is 3.7—4.3 per inch.

How thick does blown insulation need to be?

When blown into attics and wall spaces, loose-fill fiberglass offers an average R-2.5 thermal value per inch (the higher the number, the greater the insulating effect). You’d need a thickness of about 7.5 inches of insulation to match the insulating value of a batt of R-19 insulation (R-19 is a common batt value).

What is the R-value of 3 inch fiberglass insulation?

For example, a wall with 3 ½” fiberglass batting (R-value of 10.8 – 11.9) may have an overall R-value of nearly 14 because … Fiberglass Batt Insulation Standard fiberglass insulation batts or blankets provide an R-value of 2.2 to 3.8 per inch of thickness.

What is the R-value of 3 1/2 inch fiberglass insulation?

For example, standard low-density batts, at their nominal rated thickness — R-11 at 3 1/2 inches, or R-19 at 6 inches — have an R-value of about 3.1 per inch. If you compress a 6-inch R-19 batt into a 3 1/2-inch cavity, you get about R-14, or 4.0 per inch.

How many inches of blown insulation should be in my attic?

R-Value is a measure of insulation’s ability to resist heat flow. The higher the R-Value, the better the thermal performance of the insulation. The recommended level for most attics is to insulate to R-38 or about 10 to 14 inches, depending on insulation type.

How do you calculate blown insulation?

Cellulose blow-in insulation is constructed out of recycled paper. To determine how much cellulose insulation you need, take the square footage of the space and divide it by either the depth or the desired R-value. Fiberglass blow-in insulation is essentially made up of spun fibers from recycled molten glass.

Can you put too much insulation in your attic?

It’s possible to over-insulate an attic as too much will cause moisture buildup and eventually result in mold. Eventually, adding more insulation leads to diminishing returns in trapping heat as well.

What is the R-value of 3.5 inches of spray foam?

The R-value of open cell spray foam is about 3.5 per inch, although the R-value can be different depending on the product. Open cell spray foam has a low density and is many times applied in interior walls and areas that are hard to reach in a home.

How many bags of blown-in insulation will I need?

More on Calculating Insulation Needs Divide the measured square footage you obtained by 1,000 square feet to obtain the multiplication factor: 1,500 square feet/1,000 square feet = 1.5. Multiply the R-value chart number to obtain the number of bags (rounding up at the end): 40.8 * 1.5 = 61.2 or 62 bundles.

What R-value is 6 inches of insulation?

Fiberglass Insulation Batts Fiberglass blankets or rolls provide an R-value of up to 3.2 per inch, so a 6-inch fiberglass batt may achieve an R-value of 19.2, and some high-performance products are rated at R-21.

What insulation has the highest R-value per inch?

Vacuum insulated panels have the highest R-value, approximately R-45 (in U.S. units) per inch; aerogel has the next highest R-value (about R-10 to R-30 per inch), followed by polyurethane (PUR) and phenolic foam insulations with R-7 per inch.

How many inches is R60 cellulose insulation?

The average recommended level is 17 inches of R60. How much insulation in attic for Zones 5-7?.

Which blown insulation is best?

Blown-in Insulation Fiberglass, cotton, and mineral wool can all work as loose-fill material, but the far and away top choice for blown-in insulation is fiberglass. Contrary to batts insulation, blown-in fiberglass insulation is perfect for filling in tight voids around wiring, pipes, or any area with awkward framing.

Is R19 insulation better than R13?

Insulation in your walls and ceilings slows down this heat transfer. There is a direct relationship between the amount of insulation and the amount of heat transfer. The bigger the R value, the better the insulation is at slowing down the heat transfer. So R19 is better insulation than R13, and R30 is better than R19.

What is the R-value of 2 inch Styrofoam?

A wall utilizing STYROFOAM T-MASS Technology with a 2-inch exterior layer and a 4-inch interior layer of concrete along with a 2-inch layer of STYROFOAM extruded polystyrene insulation would result in a material R-value of approximately 11.33.